On May 26, 2026, a 1.2-million-gallon atmospheric storage tank at the Nippon Dynawave Packaging pulp and paper mill in Longview, Washington came apart. It released roughly 900,000 gallons of hot white liquor, a caustic process chemical, into the courtyard and nearby buildings. Seventeen employees were on the ground at the time. Eleven were killed. Three more were seriously injured, and five employees plus a firefighter were hurt badly enough to need treatment.

The Chemical Safety Board published an investigation update on August 28, 2026. It has not determined the cause, and the investigation is still open. The timeline it laid out is what every facility with older equipment should read.

What the Inspections Found

In July 2025, about ten months before the failure, a contractor inspected the exterior shell of the tank, identified in the report as G Tank. Significant portions of the carbon-steel shell measured below the calculated minimum safe thickness. The report called the tank “not fit for continued service” unless it was repaired, and flagged a high likelihood and consequence of failure. The contractor recommended an internal inspection and shell repairs.

The same contractor inspected the exterior again in October 2025 and again in February 2026. Both times, large portions of the shell were still below minimum safe thickness.

Between that July 2025 inspection and the May 2026 failure, the CSB found that the company did not conduct the internal inspection, did not make the recommended repairs, and did not take the tank out of service.

Nippon Dynawave disputes the update. Its president told employees the CSB left out important facts and context about what the company did before the incident, and noted that the update is not a final determination of cause. The final report will settle that.

Washington’s Department of Labor and Industries did not wait. After Longview it opened inspections at the state’s other kraft mills and started a targeted program covering seven non-kraft pulp and paper mills.

The Question This Raises at Your Plant

The more useful question applies to everyone, whatever the final report concludes: what happens at your facility between an inspection finding and a repair?

Most mechanical integrity programs are good at the inspection part. Someone goes out, takes readings, writes a report. The program breaks further down the line, in the gap between a finding and a work order, or between a work order and a shutdown nobody wants to schedule.

Five things to check this quarter:

  • Find your open inspection findings and read them. Not the summary, the actual reports. How many carry a recommendation that has not been completed? How old is the oldest one?
  • Check whether any finding questions fitness for service. Those are a different category from routine recommendations, and they should not be sitting in the same queue as a corroded handrail.
  • Follow one finding end to end. Pick a real recommendation from the last two years and trace it: who received it, what they did, what decision was made, who approved continued operation if no repair happened, and where that decision is written down. If you cannot reconstruct that chain, nobody else can either.
  • Ask what it would take to take the asset down. When a repair requires an outage, the honest obstacle is usually production, not engineering. Know who has authority to make that call and what evidence they would need.
  • Look at the rest of the population. Washington’s response to Longview was to go look at every similar tank in the state. If one of your assets comes back thin, the next question is what else was built at the same time, by the same method, in the same service.

Aging equipment is not the hazard by itself. Plenty of old tanks run safely for decades because somebody inspects them and acts on what the inspection says. For why high-energy failures like this one are driving chemical incident deaths upward, see Chemical Incidents Aren’t Getting More Common. They’re Getting Deadlier.

Related Posts

Chemical Incidents Aren’t Getting More Common. They’re Getting Deadlier.

Chemical Incidents Aren’t Getting More Common. They’re Getting Deadlier.

11.16.2026 Current Events
Late on Tuesday, October 20, Toledo Fire & Rescue ordered everyone within a mile of 1266 Progress Avenue to leave.…
Read More
Last Call to Update Your HazCom Program

Last Call to Update Your HazCom Program

11.16.2026 Compliance
OSHA revised the Hazard Communication Standard, 29 CFR 1910.1200, on May 20, 2024, bringing it in line with Revision 7…
Read More
Big Trouble in Big Trenches

Big Trouble in Big Trenches

11.16.2026 Current Events
October produced two enforcement actions in the same category, two thousand miles apart. In both, the ground gave way on…
Read More
cta1-img

Explore Our Live and Online Safety Courses

Learn at your own pace online or join an instructor-led live training session.